Power Cord
This part is a replacement power cord for select Hot Spring hot tubs. Made for the circulation pump Silentflo 5000 and E5.
Slide the flag terminals onto the spades inside the IQ2000 and the IQ2020 control boxes. Compatible with 1994 to current Hot Spring Highlife, Limelight, and Tiger River spa models.
*Check specs section for full list of compatible models and years.
Specifications
- Minimum flow for the circulation pump is 1 gallon in 30 seconds.
(back to top)
|
|
Removal |
- Disconnect power to the spa.
- Access the equipment compartment.
- Unplug the circulation pump from the control box.
- If the spa is filled with water, clamp the circulation pump inlet and outlet tubing with Hose Clamp Pliers.
- Remove the bonding wire and base bracket screws.
- Using Spring Clamp Pliers, slide the spring clamps located on the inlet and outlet fittings back onto the vinyl tubing.
- Remove the vinyl tubing from the pump inlet and outlet fittings.
- Disconnect the electrical cord for the old pump. Take note of the electrical hookup.
CIRCULATION PUMP INSTALLATION
- Install the original electrical cord onto the new pump.
- Reverse steps 3 to 7 of the Circulation Pump Removal instructions.
- Check for water leaks.
- Reconnect power to the spa.
- Perform a water flow test.
- Check for any air in the plumbing lines. If air does not clear, bleed off the air at the closest tubing clamp.
- Reinstall the equipment compartment door.
(back to top)
|
ELECTRICAL WIRING INSTRUCTIONS FOR SilentFlo 5000
Refer to the following instructions to install an electrical cord / ground on a no-cord SilentFlo 5000:
- Remove the end cap of the new SilentFlo 5000 pump by removing the two slotted screws on the rear black panel.
- Insert the stripped ends of the cord through the rubber gasket on the end cap.
- Connect the ground wire (green) to grounding lug located on the body of the pump.
- The other two wires should be installed into the terminal block. The pump is not affected by the polarity of the incoming power, so either wire can be installed in either terminal. NOTE: Insure that excess wire does not protrude from the rear of the terminal block. Excessive wire will cause direct shorts.
- After the wires are secure, reinstall the end cap using the two slotted screws.
- If an exterior grounding wire exists, you must attach the exterior grounding lug with single screw (provided in kit). Then attach exterior grounding wire to exterior grounding lug.
|
Item |
|
Part # |
1 |
CIRC PUMP, E5 60HZ |
74427 |
2 |
CORD, CIRC PUMP |
71434
|
Item |
Decsription |
Part # |
1 |
Main Control Board |
77089 |
2 |
Clamp Romex 3/4 |
30105 |
3 |
Plug Hole 0.3/8″ |
36043 |
4 |
Bushing Strain Relief 3/8″ |
30099 |
5a |
Cord Assy Pump 14/4 Flag 60″ |
72461 |
5b |
Cord Assy Pump 14/3 Flag 60″ |
72462 |
6 |
Strain Releif 3/8″ 7K-2 |
30098 |
7 |
Cord Circ Pump Replacement |
71434 |
8 |
Receptacle Assy Ozone |
72474 |
9 |
Plug Hole 0.50″ |
36044 |
10 |
Thermostor Hi-Limit |
72492 |
11 |
Thermistor Control |
72493 |
* |
Kit Heater Board Replacemnet |
74618 |
* |
Fuse Sloblo 1/2A 250V 5MM X 20MM |
37089 |
* |
Program Jumper Sgunt .100 |
36021 |
* |
Kit Cable Assy Press Switch |
72639 |
* |
Fuseholder |
34506 |
* |
Fuse 2 Amp 250V |
34934 |
* |
Kit 12C Comm Hub 8 Port |
74150 |
Item |
|
Part # |
1A |
Control Head Replacement |
71260 |
1B |
Control Head G & S |
** |
1C |
Control Head F & I |
** |
1D |
Control Head H & J |
** |
1E |
Control Head Replacement |
71920 |
2A |
IQ-2000 Control Box |
71382 |
2B |
IQ-2000 Control Box |
71485 |
2C |
IQ-2000 Control Box (Canadian) |
71384 |
2D |
IQ-2000 Control Box (Canadian) |
71487 |
3 |
Strain Relief 10/3 |
36022 |
4 |
Clamp Romex 3/4 |
30105 |
5 |
Cord Assy GFCI |
20120 |
6 |
Cord 14/3 XP Jet Pump |
71416 |
7 |
Bushing Strain Releif 3/8″ |
30098 |
8 |
Plug Hole 0.875″ |
36043 |
9 |
Cord Circ Pump Replacement ’97 |
71434 |
10 |
Receptacle Assy Ozone |
72724 |
11 |
Kit HSS Lampholder ’95-’00 |
71292 |
12 |
Plug Hole 0.50″ |
36044 |
13A |
Cable Assy Panel Interface |
34931 |
13B |
Cable Assy Panel Interface |
71755 |
14 |
Power Jumper Terminal Block |
71377 |
15 |
Screw Terminal Block |
71529 |
16 |
Relay 2 Pole 18VCD |
74723 |
* |
Screw IQ 2000 Cover |
36676 |
* |
Screw Mounting Bracket |
36898 |
* |
CBA Mounting Bracket |
36018 |
* |
CBA Mounting Bracket (Classic) |
36019 |
* |
Fuseholder (Canada Only) |
34506 |
* |
Fuse 2 Amp 250V (Canada Only) |
34934 |
* |
Screw Receptacle for Control Panel |
34481 |
Item |
|
Part # |
1 |
Kit CBA Advent Orca Cal |
76288 |
2 |
Kit Control Head Cal |
76269 |
3 |
Clamp Romex 3/4″ |
30105 |
4 |
Plug Hole 0.875″ |
36043 |
5 |
Bushing Strain Releif 3/8″ |
30099 |
6a |
Kit Pump Cord 14/4 2SPD STRS |
72461 |
6b |
Kit Pump Cord 14/3 1SPD STRS |
72462 |
7 |
Strain Releif 3/8″ 7k-2 |
30098 |
8 |
Cord Circ Pump |
71434 |
9 |
Ozone Receptacle |
72474 |
10 |
Thermistor Hi-Limit |
72492 |
11 |
Thermistor Control |
72493 |
12 |
Kit Heater Board Replacement |
76071 |
13 |
Fuseholder |
34506 |
14 |
Fuse 2 AMP 250V |
34934 |
15 |
Program Jumper Shunt .100 |
36021 |
16 |
Kit 12C Comm Hub 8 Port |
74150 |
17 |
Power Jumper 2 Pin |
39192 |
18 |
Power Jumper 3 Pin |
39193 |
|
Reviews
There are no reviews yet.