Circulation Timer
This part is a replacement circulation pump timer for select Hot Spring hot tubs. Consists of an on board relay and is part of the electronic timing circuit.
Opens the on-board relay for 8 hours a day in the summer timer mode. Compatible with a variety of 1996 Hot Spring Highlife and Tiger River spa models.
*Check specs section for full list of compatible models and years.
Specifications
Specifications:
- Relay 12 volt DC coil
- Operation 5 volt DC
Â
|
Removal |
- Disconnect power to the spa.
- Access the equipment compartment.
- Remove the control box.
- Locate the circulation timer board.
- Remove the two wire harnesses from J1 and J2 of the circulation timer board.
- Identify the four standoffs holding the board in place.
- With a pair of needle nose pliers, squeeze the end of each standoff while gently pulling the board upward until the board is free from all four standoffs.
- Remove the wire harness from J3 of the circulation timer board.
- Gently lift the circulation timer board so the screws in the terminal block are visible.
- Denote the location of each colored wire. It is imperative that the wires are replaced in the same locations on the new board.
- Using a small slotted screwdriver, loosen each screw until the wire can be pulled from the terminal block.
Tip: For ease of replacement, remove only one wire at a time and place it in the proper location on the new board prior to removing any subsequent wires.
- To reinstall the circulation timer board, reverse steps 1 to 11.Â
|
|